Problem Possible Cause Remedy
The unit is not Light staying on. Call for service.
cold enough.
Dirty condenser coils. Clean condenser. Refer to
CONDENSER CLEANING.
Airflow to front grille Airflow must not be
blocked. obstructed to front grille.
Refer to INSTALLATION.
Temperature not set Use the temperature
cold enough. controller to set
temperature colder.
Allow 24 hours for
temperature to stabilize.
Door is not closing Make sure no obstructions
completely. are blocking the door and
unit is level. Refer to
LEVELING THE UNIT.
Door adjustment required.
Refer to DOOR
ADJUSTMENT.
Cycle Selector Switch in Turn Cycle Selector Switch
OFF position. to ON.
Temperature Drain pump blocked. Check installation and
controller LED drain line for kinks.
flashing.
Unit malfunction. Call for service.
Noise during Certain sounds Soft sounds from the fan
operation. are normal. and water/dropping
sounds from the ice
maker will be heard.
Fresh food section Temperature control Use the temperature
on Combo units set too cold. controller to set
too cold. temperature warmer
.
The unit does Low air temperature Surrounding air
not operate. around unit. temperature must be at
least 50°F (10°C).
Unit runs but no No water being Check to see that water
ice is produced. supplied to the unit. is connected and turned
on to the unit.
40
User’s Manual
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 40