27
2. Remove the screws securing the front access panel (Figure 31).
Figure 32
3. Locate the ice cube thickness adjustment dial on the control board
(Figure 32). Turn the dial clockwise (+ number) to thicken or coun-
terclockwise (- number) to thin the ice bridge.
Ice thickness adjustment dial should be turned only one
increment (number on dial) at a time. Allow the ice maker
to stabilize for 24 hours before making further adjust-
ments. Since ice cubes in any given batch will vary, choose
cubes from the sample area for comparison when making
adjustments (Figure 33). The factory setting is +1.
CLRCO031
0
1
2
-2
3
4
5
-5
-4
-3
-1
DIAL IS FACTORY
SET TO “0”
ICE CUBE THICKNESS
ADJUSTMENT
DIAL
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 27