Vulcan-Hart 72CS Range User Manual


 
Gas Safety Valve on Standard 24" Oven
Gas Safety Valve on 30" Convection Oven
NOTE: Safety valve replacement is identical on 30
inch wide standard ovens.
4. Remove screws securing gas safety valve to
mounting bracket and remove the valve. On 24"
standard ovens, spacers are installed between
the valve and mounting bracket. Retain spacers
for reuse. Spacer locations shown in picture
25022 "Gas Safety Valve on Standard 24"
Oven".
5. Remove compression fittings and tubing from
gas safety valve for installation on replacement
valve.
Clean pipe threads and apply thread
sealant that is suitable for use with propane gases.
6. Reverse procedure to install and check for proper
operation.
TOP BURNER PILOT VALVE
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas before servicing the
unit.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
1. On the module section being serviced, loosen set
screw on top burner knobs and remove knobs
from manual valve.
2. Remove MANIFOLD COVER.
3. Remove compression nut securing pilot tube to
pilot valve.
4. Remove pilot valve from the manifold.
Fig. 30
5. Reverse procedure to install.
Clean pipe threads and apply thread
sealant that is suitable for use with propane gases.
Do not over tighten pilot valve or damage
to the threads may ocurr.
6. Check OVEN PILOT FLAME HEIGHT under
Open Top Burner Adjustment.
ENDURANCE / CHALLENGER MODULAR SERIES GAS RANGES - REMOVAL AND REPLACEMENT OF PARTS
Page 15 of 38 F45471 Rev. A (0615)