Page 20
BREW SETTINGS ?
NO YES
L BREW OZ XXX.X
(-) DONE (+)
% BYPASS XXX.X
(-) DONE (+)
BREW SETTINGS
This function allows the operator to modify the BREW
VOLUMES, BYPASS PERCENTAGES and BREW
METER for each batch size of both brew stations.
Procedure to set or modify brew volumes.
Range: 10 to 500 oz.
1. Press and hold the right hidden button until display
reads SET LANGUAGE. Press the right hidden but-
ton until display reads BREW SETTINGS ?.
2. Press YES to proceed. The display should now
read LEFT SIDE, along with MODIFY, SHOW and
NEXT.
3. Press and release MODIFY. The display should
read L BREW OZ XXX.X: and a batch light will be
blinking.
4. Using (-) and (+), set the amount of brew water, in
ounces, to be dispensed over the grounds for that
particular batch size.
5. When finished, press the other batch size and repeat
step 4.
6. When finished setting both batch sizes, press DONE.
The display should read 2 BATCH SIZES DONE?
7. If both batch sizes are not correct, press NO to
return to the L BREW OZ setup screen and repeat
steps 4, 5 and 6.
8. If both batch sizes are correct, press YES. This
will advance to the % BYPASS function. Another
alternative is to press and release either ON/OFF
button to exit the BREW OZ setup and return to the
MAIN SCREEN.
PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
LEFT SIDE
MODIFY SHOW NEXT
PRESSING NO WILL
ADVANCE TO NEXT
FUNCTION SCREEN
2 BATCHES DONE ?
NO YES
SET BOTH
BATCH SIZES
40119 071107