Bunn TITAN DUAL Coffeemaker User Manual


 
Page 22
PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
BREW SETTINGS (cont.)
Procedure to set or modify BREW METER.
Range: 1 to 14 for both batch sizes
NOTE: Using BREW METER will overwrite PULSE
BREW settings.
This function allows the operator to program the brewer
to a non-pulsed brew cycle (setting 1), or to “pulse” the
sprayhead flow on and off during a brew cycle (start and
stop the flow of water out of the sprayhead). Settings
2 thru 14 will produce pulsed brew cycles to increase
the brew strenght with 14 being the highest.
1. Press and hold the right hidden button until display
reads SET LANGUAGE. Press the right hidden but-
ton until display reads BREW SETTINGS ?.
2. Press YES to proceed. The display should now
read LEFT SIDE, along with MODIFY, SHOW and
NEXT.
3. Press and release the right hidden button until
display reads L BREW METER. A batch light will
be blinking.
4. Using (-) and (+), set the brew meter time for that
particular batch size.
5. When finished, press the other batch size and repeat
step 4.
6. When finished setting both batch sizes, press center
program button (Brewer). The display should read
2 BATCHES DONE?
7. If both batch sizes are not correct, press NO to
return to the L BREW METER: setup screen and
repeat steps 4, 5 and 6.
8. If both batch sizes are correct, press YES. This will
advance to SET PULSE BREW. To exit to the MAIN
SCREEN, press and release either ON/OFF button.
BREW SETTINGS ?
NO YES
L BREW METER X
-
I +
LEFT SIDE
MODIFY SHOW NEXT
PRESSING NO WILL
ADVANCE TO NEXT
FUNCTION SCREEN
SET PULSE BREW
NO YES
PRESS AND RELEASE
RIGHT HIDDEN SWITCH
UNTIL DISPLAY READS:
SET BOTH
BATCH SIZES
40119 071107