PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
L/R BYPASS OZ/M
This function allows the operator to view or to enter
the actual flow rate coming out of the bypass nozzle
for each side of the brewer. This is NOT used to control
the actual flow rate, but to tell the internal controller
how fast the water is flowing.
Procedure to adjust the bypass flow rate setting:
1. Press and hold the right hidden button until the
display reads SET LANGUAGE. Press the right hid-
den button until the display reads L BYPS OZ/M.
The number represents what the brewer thinks is
the flow rate out of the left bypass nozzle.
2. If the actual flow rate of the bypass is known but
is different than the number on the display, use the
(-) and (+) to enter the correct flow rate.
3. Press and release DONE. The display will now
read R BYPS OZ/M. The number represents what
the brewer thinks is the flow rate out of the right
bypass nozzle.
4. Repeat step #2 for the right bypass.
5. When finished, press and release DONE to advance
to the next function screen, CALIBRATE FLOW. To
exit programming and return to the MAIN SCREEN,
press and release either ON/OFF pad.
R BYPS OZ/M: XX.X
(-) DONE (+)
L BYPS OZ/M: XX.X
(-) DONE (+)
CALIBRATE FLOW
NO YES
40119 071107