PLUMBING HOOK UP
1. Remove the shipping cap from the fitting on the rear of the brewer.
2. Attach the flare elbow fitting (supplied separately with the brewer) to the fitting.
3. Flush the water line and securely attach it to the flare elbow fitting.
4. Turn on the water supply.
PLUMBING REQUIREMENTS
This brewer must be connected to a cold water system with operating pressure between 20 and 90 psi (138
and 620 kPa) with a minimum of 4.0 gpm from a 1⁄2" or larger supply line. A shut-off valve should be installed
in the line before the brewer. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to
reduce it to 50 psi (345 kPa). The water inlet fitting is 3⁄8" flare.
NOTE - Bunn-O-Matic recommends 3⁄8" copper tubing for all installations from the 1⁄2" water supply line. A tight
coil of copper tubing in the water line will facilitate moving the brewer to clean the counter top. Bunn-O-Matic
does not recommend the use of a saddle valve to install the brewer. The size and shape of the hole made in the
supply line by this type of device may restrict water flow.
TANK DRAIN
1. Remove screws that secure the front access panel. Remove the panel.
2. Unfasten the hose clamp at the end of the drain hose. Remove the plug.
3. Place the end of the drain hose in a drain or a container that has a minimum capacity of 16.0 gallons (60.5
liters).
4. Release the white clamp to drain water from the tank.
5. When tank is empty, close the white clamp, replace the plug, and tighten the clamp at the end of the drain
hose.
6. Replace the front panel and tighten screws.
This equipment must be installed to comply with the International Plumbing Code of the
International Code Council and the Food Code Manual of the Food and Drug Administra-
tion (FDA). For models installed outside the U.S.A., you must comply with the applicable
Plumbing/Sanitation Code for your area.
40119 030608
CE REQUIREMENTS
• This appliance must be installed in locations where it can be overseen by trained personnel.
• For proper operation, this appliance must be installed where the temperature is between 0°C to 35°C.
• Appliance shall not be tilted more than 10° for safe operation.
• An electrician must provide electrical service as specied in conformance with all local and national codes
• This appliance must not be cleaned by water jet
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given instructions concern-
ing use of this appliance by a person responsible for its safety.
If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personel with
a special cord available from the manufacturer or its authorized service personel in order to avoid a hazard.