6
CAUTION
Attempting to operate an improperly installed or out of level steamer or shifting
the steamer while operating can cause injury and equipment damage.
The steamer must be LEVEL both FRONT-TO-BACK and SIDE-TO-SIDE and
PROPERLY INSTALLED in all mounting arrangements.
Do NOT shift or move the steamer while it is operating.
Do NOT operate an improperly installed steamer.
B. Installation of a SteamChef 22CET3.1 or 22CET6.1
1. 22CET’s are typically installed with four adjustable legs. See Figures 2-1 and 2-2.
2. The appliance must be level both front-to-back and side-to-side.
3. The operating surface must be level enough to allow leveling the appliance using the adjustable
legs of the appliance or the stand.
4. The counter area selected must be capable of supporting an operating weight of:
270 pounds for a SteamChef 3.1.
350 pounds for a SteamChef 6.1.
5. If a satisfactory counter location is not available use an equipment stand:
UNISTAND 34 for one 22CET3.1 or 22CET6.1.
UNISTAND 25 for two 22CET3’s, one on top of the other.
Model No. ES263044 Stacking Stand for two 22CET6.1’s, one on top of the other.
DANGER
Improper Lifting can cause DEATH, INJURY, and EQUIPMENT DAMAGE
A 22CET3.1 weighs 270 pounds, and a 22CET6.1 weighs 350 lbs.
Use enough workers with experience lifting heavy equipment to place the
appliance
on the supporting surface.
DANGER
Improper installation, adjustment, alteration, service or maintenance can cause DEATH,
INJURY, AND EQUIPMENT DAMAGE
Read and understand the installation, operation and maintenance instructions before
installing, using, or servicing this equipment.
DO NOT INSTALL a SteamChef steamer if it is damaged or if damage is suspected.
Install the SteamChef steamer according to the policies and procedures outlined in this manual.