9
Figure 3
-
7
Steam Vent
(SteamChef
3.1 Shown)
H. Install the Rear Vent
• For 22CET’s not on stacking stands:
1. Using pipe thread sealant (not provided), install the provided brass street ell into the bulkhead
fitting on the rear of the 22CET. See Figure 3-7.
2. Connect the drain to a free air vented drain line. See Figure 3-8.
I. Connect the Free Air Vented Drain Line
NOTICE: Furnishing and installing drain lines and drainpipe is the responsibility of the Installer/Owner.
The following restrictions and requirements are critical to the safety of personnel and
equipment, and must not be violated under any circumstances:
1. The drain lines must be installed in compliance with the Food Code (latest edition) of the Food and
Drug Administration (FDA), and any other applicable national, state, or local codes and regulations.
2. The drain line must be free air vented, have gravity flow from the appliance, and terminate
outside the perimeter of the appliance.
3. Free air venting requires a minimum 1” clearance between the end of the drain line and the top of
the floor drain. See Figure 3-8.
4. Do NOT install the appliance directly over a drain. Steam rising up out of the drain will adversely
affect operation, hamper cooling air circulation, and damage electrical and electronic components.
5. Do NOT connect the appliance’s drain connection to any drain material that cannot sustain 180
o
F.
6. Do NOT connect any other drain from any other equipment to the drain line of this appliance.
7. Do NOT connect the drain outlet extension line directly into a floor drain or a sewer line.
DEATH, INJURY, EQUIPMENT and PR
OPERTY DAMAGE
will result from improper installation of drain outlet lines.
Install free air vented drain lines as described in this manual.
DRAIN
VENT