Cleveland Range 22CET6.1 Electric Steamer User Manual


 
10
1" Clearance
Minimum
8. Do NOT connect this appliance’s drain directly to drains or to the plumbing of any other
equipment. (Except when using a Cleveland Range Stacking Stand.)
9. Do NOT install a trap or shutoff in the drain line.
10. Drainpipe Size and Length Guidelines:
Do NOT make a drainpipe outlet extension more than 12 feet long.
Do NOT use more than three elbows.
Up to 6’ pipe: 1 1/2-inch pipe and fittings are acceptable.
Up to 2 elbows: 1 1/2-inch pipe and fittings are acceptable.
6’ to 12’ pipe: 2-inch pipe and fittings are required.
3 elbows on any extension: 2-inch pipe and fittings are required.
11. Connect the drain to the appliance. See Figure 3-8.
a. The steamer is supplied with a 1 1/4-inch pipe connection at the bottom of the drain tee. Do
not reduce pipe size.
b. Make sure the drain pipe is the correct size. See Item 10.
c. While assembling the pipes and fittings of the drain outlet extension, use non-hardening pipe
thread sealant.
d. Thread fittings together FINGER TIGHT ONLY! DO NOT USE A WRENCH!
Figure 3
-
8
Typical Drain Connection
(SteamChef 3 Shown)