Emerson Process Management 7951 Ventilation Hood User Manual


 
Chapter 10 Configuring your instrument by using wizards
Page 10.3
10.4 Quick-start Guide ( Set-up Wizards )
Wizard Measurement Task Page
Density 1
Gas density measurement (nominated as density ‘A’) from a
single transducer that is connected to “Density input 1”.
10.6
Density 2
Gas density measurement (nominated as density ‘B’) from a
single transducer that is connected to “Density input 1”.
10.8
Density 1 & 2
Gas density measurements (nominated as density ‘A’ and
density ‘B’) from two transducers that are connected to “Density
input 1” and “Density input 2”.
SG 1
Specific gravity measurement (nominated as SG ‘A’) from a
single transducer that is connected to “Density Input 3”.
10.10
SG 2
Specific gravity measurement (nominated as SG ‘B’) from a
single transducer that is connected to “Density Input 4”.
10.11
SG 1 & 2
Specific gravity measurements (nominated as SG ‘A’ and SG
‘B’) from two transducers that are connected to “Density input 3”
and “Density input 4”
10.12
Line density
Density ‘A’
Density ‘B’
10.13
Base density
Base density ‘A’
Base density ‘B’
10.16
Specific gravity
SG ‘A’
SG ‘B’
10.18
Temperature
Line temperature
Density temperature ‘A;
Density temperature ‘B’
10.20
Pressure Line pressure 10.22
Transmitters
Live nitrogen measurement from an analogue input
Live carbon dioxide measurement from an analogue input
Live energy measurement from an analogue input
10.24
Special Calc. Special equations 1 and 2 10.27
Analogue outputs
10.28
Alarms User defined alarms 10.29
Multi-view Multi-page multi-view
10.30
Full Setup A collection of wizards for configuring a whole system
10.31