Garland Convection Microwave Oven Convection Oven User Manual


 
Part # 1955203 (12/06)Page 12
To set the oven temperature, press the SET key again.
e TEMP LED will light and the oven temperature
can be set by rotating the dial on the controller until the
desired temperature is displayed. Pressing the SET key
again will light the HOLD LED allowing the operator
to set the hold temperature in the same manner.
NOTE: If the hold temperature is not set, the default
hold temperature is °F (°C) or the last programmed
temperature. (Hold temperature range is °F (°C)
to °F (°C).
When the core temperature is reached the display will
sound and flash “DONE” for  seconds. Automatically,
the display will switch to count “UP” the time the oven
is on hold.
Setting Setback Feature
To set or change the setback settings, press and hold
the SETBACK key for two seconds. e TEMP LED
will light and a temperature will be displayed. Set the
temperature using the dial, then press the SET key. e
TEMP LED will go out and the TIME LED will light
(“Time” is factory set at ). Set the time using the dial,
then press the SET key. Press the SET key one more
time to exit programming.
NOTE: To disable the setback function, set the time
to zero.
Master 475 Electronic
Programmable Control
Manual Cooking
1. Press SET key – TEMP LED will light.
2. Set temperature using the dial (factory preset at
350°F).
3. Press SET key – FAN LED will light.
4. Select fan mode using one of the three (3) fan keys
(HIGH, LOW, PULSE) – the selected FAN LED
will light.
5. Press SET key – TIME LED will light.
OPERATING INSTRUCTIONS Continued