Part # 1844063 (08/06) Page 9
ASSEMBLY INSTRUCTIONS Continued
7. A separate shut-off valve for each oven must be
provided. It should be as close as possible to the
place where the gas line goes into the oven. It must
be located so that it is easily accessible. A handle or
wrench should be chained to the valve where it will
always be at hand.
8. For a stack of two ovens, two shut-off valves, one
for each oven must be provided.
ADJUSTMENTS
Gas Pressure Adjustments
All GPD Series ovens are equipped with fixed orifices
and cannot be adjusted for gas flow: If necessary, pressure
adjustments can be made at the pressure regulator
(located on the combination gas valve).
A pressure tap is supplied with the unit and it is installed
on the manifold, downstream of the main valve. e gas
pressure must be checked when the unit is installed, to
ensure that the unit gas pressure is the same as specified
on the rating plate.
IMPORTANT:
All gas burners and pilots need sufficient air to
operate and large objects should not be placed
in front of this oven, which would obstruct the
airflow through the front.
Objects should not be placed on main rear of oven
while in use.
Flame & Air Mixture Adjustment
After the pilot burner is ignited, when heat is desired, turn
gas cock dial to “ON” position and set the thermostat
dial to the desired temperature. e oven burner flame
should always have a blue appearance. is indicates a
3/4 NIPPLE
3/4" COUPLING
3/4" x 3/4" x 1" TEE
6 1/2" NIPPLE
3/4" NIPPLE
3/4" COUPLING
1" NPT 90° STREET ELBOW
5 3/4" NIPPLE
3/4" UNION
3/4" NPT 90° STREET ELBOW
3/4" NPT 90° STREET ELBOW