Heartland 3530 Range User Manual


 
2
Metro / Legacy Series
Set Up and Assembly
Safety Instructions
Please check for any damage that may have
occurred during shipping. In the unlikely event
that you find any shipping damage, inform your
dealer immediately!
Legacy and Metro ranges consist of the range
body and the splashback. The splashback is
fastened to the back of the stove for shipping
purposes.
Tools required for assembly:
Screwdriver
Utility knife
Level
Metal shears
Hammer
You must have a qualified electrician con-
nect the new range to be sure all electrical
codes and regulations are observed except
when range is equipped with a cord and
plug. A qualified gas technician must install
this appliance to ensure local installation
codes and regulations are observed.
Preparing the Installation Site
Find the appropriate clearance/installation
diagram for your range on the following pages.
(see fig 1 & 2) Diagrams include installations
with an exhaust hood.
These diagrams will outline the required opening
for your range and clearances to cupboards,
electrical outlets, and gas outlet. Site prepara-
tion can be made to have these utilities ready
prior to receipt of the range and splashback.
Also required before installation of your range,
is the placing of the Anti -tip bracket.
Follow this procedure to install the anti tip
bracket.
1) the anti tip bracket package (complete with
screws) is found in the accessory box inside the
oven.
2) on the wall measure up from the floor 5 5/8”
and mark that position with a pencil, this is the
correct height of the tab on the bracket.
3) at the 5 5/8” height locate a wall stud along
that horizontal plane.
4) fasten the bracket to the wall stud at the 5 5/8
height with the 2 screws supplied.
5) use the two holes immediately above the tab
in the left side of the bracket, if there is a block-
age preventing the use of these holes, use the
alternate holes in right side of the bracket.
use these holes to mount
bracket
this tab fits over the bottom panel of
the appliance, when the appliance is
slid into place.
alternate mounting holes
Anti - tip bracket diagram
Installation Clearances
Should the range be installed adjacent to a refrig-
erator, it is important that there be a minimum of 5”
(30 cm) of space between the two appliances for
proper air circulation.
Installation of cabinet storage space above the sur-
face burners should be avoided at all costs to elimi-
nate the risk of burns or fire by reaching over the
surface burners. If combustible materials are
present above the cooking surface they should be
at a minimum distance of 36” from the surface burn-
ers.