Heartland 3530 Range User Manual


 
6
Metro / Legacy Series
Edges of
counter top
must be finished
G
H
I
JK
O
cupb
mus
26”
oard depth
t
not exceed
L
M
P
Q
R
S
S
1
N
Gas Inlet
Anti-tip
bracket
T
Clearances
• Minimum distance between the range and a side wall above the cooking top surface is 6” (see dim "O" in Table 2 below)
• 0” Clearance to the back of the stove may be obtained when installing the appliance against a non - combustible wall or with the
installation of our Splashback Kit. Responsibility for ensuring that the rear wall is non - combustible lies with the owner or end
user. (check local building codes) - if wall behind stove is deemed combustible and our splashback kit is not installed, then the
minimum spacing from the back of stove to nearest combustible wall is 6”
Electrical requirements:
• Electrical hookup must be done by a licenced electrician
• 240 Volts 60Hz 5.6 kW 3 prong plug for U.S. and 4 prong for Canadian installations.
(5 ft-1.5 m power cord included) New installations for the U.S. may require a four prong
plug, please confirm prior to ordering.
Gas Requirements:
• Gas hook-up must be done by a licensed gas fitter.
• Pressure requirements: Natural gas: 6” W.C. (min); LP gas: 11” W.C. (min)
• Connection: 1/2” NPT • 5/8” minimum diameter flex line.
• An accessible
manual shut off
valve must be in-
stalled at the appli-
ance.
• Natural Gas/Pro-
pane Conversion
kits are available -
must be done by a
licensed gas fitter
Anti Tip Bracket:
Bracket included
with every stove.
When properly in-
stalled, will prevent
stove from tipping
forward if down-
ward force is ap-
plied to an open
door.
Figure 1 Table 1
Dim 36" Legacy
A
1
28 3/4" (73cm)
to front of stove
A
2
31 1/2" (80 cm)
to edge of oven door handle
B
36 1/8" (92cm)
C
36" (91cm)
D
17 1/2" (45cm)
E
1
standard 42 1/8 "(106cm)
E
2
low profile: 38" (97cm)
E
3
high back w/ shelf:
56 1/8" (143cm)
Clearance Diagrams - 36” Legacy
Dim 36" Legacy
G
Maximum 26"" (66cm)
H
36" (92.5cm)
I
12" (30.5cm)
J
37" (94cm)
K
5 5/8"(14.5cm)
L
2" (5cm)
M
18" (46cm)
N
16" (41cm)
O
6" (15cm) min left and right side
P
13" (33cm)
Q
SPECIFY WIDTH OF HOOD
R
24" (61 cm)
S
30" min to 36" max (76-92 cm)
for standard and high back guard
S
1
30" min to 32" max (76-82 cm)
for low profile back guard only
T
18" (45cm)
* U.S. models only: J=36 1/2”
*
For proper performance a 900 CFM vent
hood is required on all 36" Metro ranges
to ensure adequate and proper ventila-
tion. For superior ventilation we
recommend using a 42” hood, however
a 36” hood is adequate.
Note: If range must stand beside
a refrigerator, it is important for
proper air circulation.There must
be at least 5” (125 mm) of space
between the two appliances.