STEAM USAGE / REQUIREMENTS – POUNDS PER HOUR
Model
Tank Heat
Booster
110 F Incoming
Water, 75 F Rise
Dryer
TOTAL
Tank Heat &
Booster
TOTAL
Tank Heat,
Booster, & Dryer
FT1000-Base 209
47 - 256
-
FT1000S-Base 171
47 - 218
-
FT1000-ER 213
42 - 255
-
FT1000S-ER
171
42 - 213 -
FT1000-ER-BD
213
42 30 255 285
FT1000S-ER-BD
171
42 30 213 243
Steam Tank Heaters – Condensate Return Lines
The wash tank, power rinse tank, and dual rinse tank may be equipped with steam
coil tank heaters. If steam coils are used, a condensate return, gravity type, must
be connected for each coil. Bucket-type traps are furnished. The connection points
forthecondensatereturnlinesforallthreecoilsare¾”NPTfemalepipettings.
Condensate lines must not be plumbed uphill.
Steam Booster Heater – Condensate Return Line & Relief Valves
The connection point for the condensate return line for the steam booster heater is
a¾”NPTfemalepipetting.Buckettypetrapisfurnished.Condensatelinesmust
not be plumbed uphill. The steam booster heater is equipped with a steam relief
valvethathasa1”NPTfemalepipettingthatmustbepipedtoanopendrain
receiverintheoor.Thesteamboosterheaterisalsoequippedwithahotwater
reliefvalvethathasa¾”NPTfemalepipettingthatmustbepipedtoanopen
drainreceiverintheoor.
The steam booster thermostat (bulb and capillary tube style) is mounted and wired
in the main control box. The bulb and capillary tube is shipped with the control
box on the center section. During installation, the bulb and capillary tube must be
carefully uncoiled and routed to the steam booster and inserted in the booster outlet
hotwaterlinethroughthesuppliedtting.Insertthebulbtwo-thirdsofthewayinto
the booster body (refer to tag attached to thermostat, F-44107).
Steam Blower Dryer (When Equipped) – Condensate Return Line
NOTE: The steam blower dryer is equipped with a steam on/off valve. The steam
supply is ON when the machine is ON and OFF when the machine is OFF.
The steam blower dryer has a condensate return, gravity type; bucket type trap
furnished. The connection point for the condensate return line for the coil is a ¾”
NPTfemalepipetting.Condensatelinesmustnotbeplumbeduphill.