Hobart HP15E Fryer User Manual


 
– 12 –
Insertion and removal of the filters is described in the CLEANING section of this manual.
Indicator Lights
Interlock Light When lit, indicates all hood interlock switches are closed.
ANSUL
®
Light When lit, indicates the fire suppression system is cocked and charged.
FIP (Filter-In-Place) Light When lit, indicates all filters are properly installed.
Sail Light When lit, indicates the exhaust blower is operating and moving an
adequate volume of air.
Reset Pushbutton Switch Momentarily overrides sail switch to allow the exhaust blower to start.
BEFORE FIRST USE
WARNING: DISCONNECT ELECTRIC POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT
SWITCH TO INDICATE YOU ARE WORKING ON THE CIRCUIT BEFORE CLEANING.
Clean the pressure fryer and hood (if so equipped) with warm soapy water. Rinse thoroughly and drain
in a drainage receptacle. Wipe completely dry with a soft, clean cloth. Clean all fryer and hood (if so
equipped) accessories. Rinse thoroughly after cleaning and wipe dry.
Fig. 17 Fig. 18
Install the air filter onto the center set of pegs (Fig. 17), again making certain that the switch actuator
is engaged. The grease filter is installed last at the front of the hood (Fig. 18). It rests into front and
rear support channels. Pull the handles down to ensure a close fit and to engage the interlock switch
actuator.
PL-40088-1
AIR FILTER
PL-40089-1
GREASE FILTER