Hobart HP15E Fryer User Manual


 
– 22 –
Fig. 25
Fig. 27
7. Drain the condensation tank (Fig. 27). The condensation tank drain valve is located behind the
front access door at the lower right.
Attach the drain pipe extension (supplied) to the condensation tank drain line (Fig. 27). Place
a pail below the extension and drain the condensation tank by turning the handle clockwise.
After draining the condensation tank, turn the handle counterclockwise to close the drain valve,
then remove the drain pipe extension before closing the door.
When cleaning the area immediately surrounding the fryer (floor, walls), it may be necessary to move
the fryer from its installed position.
WARNING: SPILLING HOT OIL CAN CAUSE SEVERE BURNS. DO NOT MOVE THE PRESSURE
FRYER WITHOUT DRAINING ALL OIL FROM THE TANK.
Unplug the electrical cord.
Fig. 26
6. Raise the lid by pulling the back knob (Fig. 25) out and lifting the lid up. Hold the back knob out
until you reach the desired height. Release the knob to hold the lid in that position. Wipe the under
part of the lid clean, including the diaphragm (Fig. 26).
PL-41468-1
DIAPHRAGM
BACK KNOB
PL-41596-2
PL-53522
EXHAUST PIPE
SUPPLIED BY INSTALLER
EXHAUST PIPE
CONDENSATION
TANK
AC CONDUIT
AC INSPECTION BOX
1 1/4" PIPE
THREAD
DRAIN VALVE,
CONDENSATION
TANK