Hobart HP15E Fryer User Manual


 
– 25 –
12
OCLOCK
3
OCLOCK
6
OCLOCK
9
OCLOCK
PL-50399
Fig. 32
Pop-Off Valve
Once a week, operate the pop-off valve by lifting the ring up (see Fig. 24) and then releasing it.
Monthly Cleaning
Condensation Tank
1. Open the access door and screw the drain pipe extension to the end of the condensation tank
drain valve (see Fig. 27) at the lower right side of the pressure fryer.
2. Place a pail below the extension, open the drain valve, and drain the condensation from the tank.
Clean the condensation tank by removing the cleanout port cover from the top of the tank and
rinsing the tank with hot water.
3. If the pressure fryer is equipped with the optional ventless exhaust hood, empty and wash the drip
cup below the grease filter (see Fig. 12).
Optional Ventless Exhaust Hood (Fig. 33)
Clean the air filters and hood weekly.
Fig. 33
CHARCOAL FILTER
AIR FILTER
GREASE FILTER
TRAY
PL-50755