6.19 OPERATOR TRAINING.
Take time to explain the correct operation and cleaning of the Legacy mixer to the users referring to
this manual. Leave this manual with the operator and explain that it is important to use it for further
reference.
7.0 MIXER MAINTENANCE.
A HOBART TRAINED AND COMPETENT PERSON SHOULD CARRY OUT
SERVICING.
Do not remove any covers or loosen any fittings while the mixer is operating.
Ensure the electrical supply has been isolated before attempting to service or
move the mixer.
WARNING: UNPLUG MACHINE POWER CORD BEFORE BEGINNING ANY MAINTENANCE
PROCEDURES.
WARNING! THE ELECTRONIC DRIVE CONTROL IS FITTED WITH HIGH VOLTAGE
CAPACITORS. ISOLATE THE MIXER FROM THE MAINS AND ALLOW THE CAPACITORS
TO DISCHARGE FOR 5 MINUTES BEFORE REMOVING ANY COVERS.
7.1 LUBRICATION.
7.1.1 SLIDEWAYS.
The slideways (Fig. 16) should be lubricated approximately twice a year. To reach these
areas, fully lower the bowl support and remove the apron, which is secured by slotted
screws. Wipe a thin coat of Lubriplate 630AA on the bowl pad area of the bowl supports and
on each slideway. Replace the apron and secure with screws. Refer to the recommended
spare parts section for Lubriplate oil part number.
NOTE: Do not remove sensor holder screws to remove apron.
Sensor
Holde
r
Screws
A
p
ron
Fig. 17
Fi
g
. 16
Slideway