Jenn-Air's ventilation system is designed to capture both cooking fumes and smoke
while grilling. If the system does not, these are some dueling installation situations to
check:
6" diameter round or 31/4'' x 10" rectangular ducting should be used for duct lengths
10'-60'. Note: 5" diameter round dueting must be used if the duct length is 10'
or less.
No more than three 90° elbows should be used. Distance between e_bows should
be at least t 8".
Recommended Jenn-Air wall cap should be used. Make sure damper moves freely
when ventilation system is operating.
There should be a minimum clearance of 6" for cooktop installed near a side wall.
If there is not an obvious improper installation, there may be a concealed problem such
as a pinched joint, obstruction in the pipe, etc. Installation is the £espon_ of the
installer and questions should be addressed first by the installer. The installer should
very carefully check the ducting installation instructions.