To adjust tl_c lAD settling:
1. Light burner and set control knob for low flame.
2. Remove control knob from valve stem.
CAUTION:
Never use a metal blade to pry knob off. If knob cannot be easily removed,
tuck the folds of a cloth dishtowel under the knob skirt and pull the towel
upward with steady, even pressure.
3. Insert a slender, thin-blade screwdriver
_/_ COUNTERCLOCKWISE
into the recess at center of valve stem TOINCREASEFLAME
and engage blade with slot in adjusting SJZE
screw. CLOCKWISE
TO REDUCE
4. Turn center stem adjusting screw slightly FLAMES_ZE
tO set flame size. Note: Turn clockwise
to reduce or counterclockwise to in-
crease flame size.
VALVE
5. Replace control knob when adjustment STEM--
is completed.
Proper adjustment will produce a stable, steady blue flame of minimum size. The
final adjustment should be checked by turning knob from Hi to Lo several times
without extinguishing the flame.
This adjustment, at the Lo setting, will automatically provide the proper flame size
at Meal setting.