30
CDVX Series Direct Vent Gas Fireplace
20012253
Logs
The 36CDVX logs are shipped in place. If a log is
broken, refer to the replacement parts list for a replace-
ment. Figure 63 shows where the logs are secured to
the fireplace.
RN/RP & EN/EP Models
For units equipped with “HI/LO” valves the flame
adjustment is accomplished by rotating the “HI/LO”
adjustment knob located near the center of the gas
control valve. (Figs. 64)
Flame & Temperature Adjustment
It is important to periodically perform a visual check
of the pilot and burner flames. Compare them to the
illustrations. (Figs. 65 & 66)
If the flame patterns appear abnormal contact a
qualified service provider for service and adjustment.
Flame Characteristics
L
O
H
I
FP390
FLAME ADJUSTMENT KNOB
11/21/96
Turn
counterclockwise
to increase
flame height
Turn clockwise
to decrease
flame height
SIT 820 Valve
Fig. 64 Flame adjustment knob for SIT valve.
SIT RN/RP
FP1541
Fig. 65 Correct pilot flame appearance.
Lava Rock
Ember Material
Figure 63
Ember Material and Lava Rock Placement
Separate the ember material into small pieces, roughly
1/2” in diameter and place on the front burner tube. Do
NOT pack down, leave in fluffy, loose condition for most
realistic ember effect. (Fig. 62)
The lava rock provided with this fireplace
must be placed on the firebox base
around the burner assembly. (Fig. 63)
Under no circumstances should this lava
rock be placed on any part of the burner.
LG480
Red Glow, Yellow Tips
LG481
Yellow Flame
Figure 66