Majestic Appliances 36CDVXTRN Ventilation Hood User Manual


 
7
CDVX Series Direct Vent Gas Fireplace
20012253
Top of Unit to Ceiling ............................... 36” (914 mm)
Front of Unit to Combustibles .................. 36” (914 mm)
Appliance
Top .......................................................... 0” (0 mm)
Bottom ..................................................... 0” (0 mm)
Side ......................................................... 0” (0 mm)
Back ........................................................ 0” (0 mm)
Venting
Concentric sections of DV Vent
Top, bottom & sides .............................. 1” (25 mm)
Flex Vent ..................................................
7/8” (22 mm)
NOTE: Hood must be permanently installed with
three (3) sheet metal screws supplied in fireplace.
(Refer to hood installation in this manual.)
Mantels
The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For the correct mounting height and widths refer to
Figs. 4a and 4b, and the following Mantel Charts.
The fitting of a bay window trim kit does not effect
the distances and reference points referred to in the
diagram and chart.
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
When using paint or lacquer to finish the mantel, such
paint or lacquer must be heat resistant to prevent
discoloration.
Clearance to Combustibles
CFM170
J
F
G
H
I
Mantel
Leg
CFM164a
Mantel Leg Chart
06/22/01 sta
Black
Surround
Face
CFM170
DV Builder Front
View
O
N
M
L
K
Side of
Combustion Chamber
CFM164a
Mantel Mantel Leg FromSide
Ref. Leg Depth Ref. of Comb. Opening
F 10” (254 mm) K 11¹⁄₂ (292 mm)
G 8” (203 mm) L 9
¹⁄₂ (241 mm)
H 6” (152 mm) M 7¹⁄₂ (191 mm)
I 4” (101 mm) N 5
¹⁄₂ (140 mm)
J 2” (51 mm) O 3¹⁄₂ (89 mm)
Fig. 4b Combustible mantel leg minimum installation.
CFM146
A B C D E
V
W
X
Y
Z
Fireplace
CFM146
DV Mantel Chart
7/5/01 sta
Hood
Top of Combustion
Chamber
Mantel Chart
Mantel Shelf or Mantel from Top of
Ref. Breast Plate Depth Ref. Combustion Chamber
V 10” (254 mm) A 17” (432 mm)
W 8” (203 mm) B 15” (381 mm)
X 6” (152 mm) C 13” (330 mm)
Y 4” (101 mm) D 11” (279 mm)
Z 2” (51 mm) E 9” (229 mm)
Fig. 4a Combustible mantel minimum installation.
Standoff
Finish Wall
Noncombustible
Material
A) Flat on wall B) Cross corner C) **Island
D) Room divider E) Flat on wall corner F) Chase installation
Y) Refer to “Clearance to Combustibles” Section
NOTE: (Fig. 3)
** Island (C) and Room Divider (D) installation is possible as
long as the horizontal portion of the vent system (X) does not
exceed 20’ (6 m) with a minimum vertical of 4’ (122 cm). See
details in Venting Section.
Locating Your Fireplace
Y
E
A
B
C
D
F
Y
B
X
LU584-R
Locating unit
2/23/01 sta
X
LU584-R
Fig. 3 Locate gas fireplace.
3/4” (19 mm) Scribe
Moulding for use
with MHSC Cabinets
3/4” (19 mm) Scribe
Moulding for use with
MHSC Cabinets