Majestic Appliances 36CDVXTRN Ventilation Hood User Manual


 
39
CDVX Series Direct Vent Gas Fireplace
20012253
FK12
This auxiliary fan system increases the efficiency of the
circulation of the heating air.
The FK12 Fan Assembly is a fixed speed fan system
and does not allow for variable speed control.
Specifications
115 Volts / 60 Hz / 56 Watts.
Maintenance
The fan itself does not require regular maintenance,
however periodic cleaning of the fan and the
surrounding area is required.
Check the area under the control door (lower louvre
assembly) and in front of the fan and wipe or vacuum
this area at least once a month during the operating
season.
Installation
The fan assembly is supplied fully wired eliminating
the need for a licensed electrician to carry out the
installation.
1. Remove the lower Louvre assembly. Move the
fan & bracket assembly around the gas valve and
lines to locate the unit against the back wall of the
appliance, resting on the base.
2. With the protective cover removed from the self-
adhesive ‘Velcro’ strips apply mild pressure to the
fan & bracket unit to secure the strips to the metal
panels. No further securing is required.
3. Power to the fan can be supplied by plugging the
supplied lead into a conveniently located wall socket
or by using the receptacle in the bottom of the unit.
Optional Accessories Available
Fan Kits
FP1602
FK12
fan install
12/05
Fan
Gas Lines
Valve
FP1602
Fig. 76 FK12 fan placement.
Receptacle
The fireplace, when installed, must be
electrically connected and grounded in
accordance with local codes or, in the
absence of local codes, with the current
CSA C22.1 Canadian Electric Code.
For USA installations follow the local
codes and the national electrical code
ANSI/NFPA No. 70.
Should this fan require servicing or repair
the power supply must be disconnected.
Any electrical rewiring of this fan must be
done by a licensed electrician.
Wiring Instructions
Remote Controls
Optional remote control units are available to control
different functions of the appliances.
Model Function/s Controlled
RCI ON/OFF
RC2 ON/OFF and Temperature
IMTFK Wall mounted thermostat control
(must be used in bedroom installations)
Optional Trim
The Perimeter trim is designed to enhance the look of
the fireplace.
Model Description
36CDVTK Perimeter Trim Black