Conversion Instructions (Models CPL1100AD*, CGL1100AD*)
-9-
GAS CONVERSION
General
All ranges are equipped with fixed orifices and with a
convertible appliance pressure regulator. The unit model
number plate states which gas it was adjusted for at the
factory. To convert the unit to either Natural gas or LP gas
will require the replacement of orifice hoods, adjustment
of the air shutters on the burners and adjustment of the
appliance pressure regulator converter cap.
SEE INSTRUCTIONS FOR GAS CONVERSION
LOCATED ON THE BACK OF THE RANGE.
Inlet pressure to the appliance pressure regulator should
be as follows for both operation and c hecking of appliance
pressure regulator setting:
INLET PRESSURE IN NATURAL LP
INCHES OF WATER COLUMN
GAS GAS
Minimum 5 11
Maximum 14 14
HOW TO REMOVE RANGE
FOR SERVICING
Follow these procedures to remove appliance for
servicing:
1. Shut off gas supply to appliance.
2. Disconnect electrical supply to appliance, if equipped.
3. Disconnect gas supply tubing to appliance.
4. Slide range forward to disengage range from the
anti-tip bracket. (See page 4).
5. Reverse procedure to reinstall. If gas line has been
disconnected, check for gas leaks after reconnection.
NOTE:
A qualified servicer should disconnect and
reconnect the gas supply.
The servicer MUST
follow installation instructions
provided with the gas appliance connector and the
warning label attached to the connector.
6. To prevent range from accidentally tipping, range must
be secured to the floor by sliding rear leveling leg into
the anti-tip bracket.
SERVICE - PARTS INFORMATION
WHEN YOUR RANGE REQUIRES SERVICE OR
REPLACEMENT PARTS, CONTACT YOUR DEALER
OR AUTHORIZED SERVICE AGENCY. PLEASE GIVE
THE COMPLETE MODEL AND SERIAL NUMBERS OF
THE RANGE WHICH IS LOCATED ON THE RANGE
MODEL NUMBER PLATE.