Maytag AGR5712ADB/Q/S/W Range User Manual


 
C–12 16023522 ©2004 Maytag Services
Conversion Instructions (Models AGR4400AD*, AGR4412AD*,
CG31400AD*, CG31600AD*, CGR1110AD*, CGR1415AD*, CGR1425AD*,
CP31600AD*, MGR4451AD*, MGR4452AD*, PGR4420LD* )
Gas Conversion
General
All ranges are equipped with fixed orifices and with a
convertible appliance pressure regulator. The unit model
number plate states which gas it is adjusted for at the
factory. To convert the unit to either Natural gas or LP
gas will require the replacement of the orifice hoods, and
the adjustment of the air shutters on the burners and
adjustment of the appliance pressure regulator converter
cap.
Inlet pressure to the appliance pressure regulator should
be as follows for checking the appliance pressure
regulator setting:
INLET PRESSURE IN NATURAL LP
INCHES OF WATER COLUMN
GAS GAS
Minimum 5 11
Maximum 14 14
Appliance Pressure Regulator Conversion
The unit appliance pressure regulator must be set to
match the type gas supply used. If converting from
natural gas to LP gas, the appliance pressure regulator
must be converted to regulate LP gas. If converting from
LP gas to natural gas, the appliance pressure regulator
must be converted to regulate natural gas.
The regulator can be accessed from behind the range,
under the cooktop.
To convert the appliance pressure regulator from one gas
to another, remove cap and forcibly snap out plastic
plunger from bottom of cap. Turn plunger over and
forcibly snap back in original location (Figure 1).
NOTE: Plunger MUST
snap into position; the gas type
you are converting to must be visible on lower side of
plunger.
FIGURE 1
8101P651-60
(06-04-00)