Conversion Instructions (Model LPR1115AD*)
-9-
 

All ranges are equipped with fixed orifices and with a
convertible appliance pressure regulator. The unit model
number plate states which gas it was adjusted for at the
factory. To convert the unit to either Natural gas or LP gas
will require the replacement of orifice hoods, adjustment
of the air shutters on the burners and adjustment of the
appliance pressure regulator converter cap.
    
      
Inlet pressure to the appliance pressure regulator should
be as follows for both operation and checking of appliance
pressure regulator setting:
    
   
 
Minimum 5 11
Maximum 14 14
   


      

1. Shut off gas supply to appliance.
2. Disconnect electrical supply to appliance, if equipped.
3. Disconnect gas supply tubing to appliance.
4. Slide range forward to dis engage range from the
anti-tip bracket. (See page 4).
5. Reverse procedure to reinstall. If gas line has been
disconnected, check for gas leaks after reconnection.
klqbW
A qualified servicer should disconnect and
reconnect the gas supply.
The servicer 
follow installation instructions
provided with the gas appliance connector and the
warning label attached to the connector.
6. To prevent range from accidentally tipping, range must
be secured to the floor by sliding rear leveling leg into
the anti-tip bracket.
 
When your range requires service or replacement parts,
contact your dealer or authorized service agency. Please
give the complete model and serial number s of the range