Maytag AGR5712ADB/Q/S/W Range User Manual


 
©2004 Maytag Services 16023522 C–5
Conversion Instructions (Model CPR1100AD*)
General
All ranges are equipped with fixed orifices and with a
convertible appliance pressure regulator. The unit model
number plate states which gas it was adjusted for at the
factory. To convert the unit to either Natural Gas or LP
Gas will require replacement of the orifice hoods,
adjustment of the air shutters on the burners and
adjustment of the appliance pressure regulator converter
cap or plunger.
Inlet pressure to the appliance pressure regulator should
be as follows for both operation and checking of appliance
pressure regulator setting:
INLET PRESSURE IN NATURAL LP
INCHES OF WATER COLUMN
GAS GAS
Minimum 5 11
Maximum 14 14
Appliance Pressure Regulator Conversion
The unit appliance pressure regulator must be set to
match the type of gas supply used. If converting from
Natural Gas to LP Gas, the appliance pressure regulator
must be converted to regulate LP Gas. If converting from
LP Gas to Natural Gas, the appliance pressure regulator
must be converted to regulate Natural Gas.
To Convert The Appliance Pressure
Regulator From One Gas To Another:
Remove cap, turn converter cap or plunger over and
replace cap. (See figure 1).
NOTE: What you read on the converter cap or plunger
after conversion is the type gas setting for that regulator,
i.e. If you read NAT. the regulator is set for Natural Gas.
Gas Conversion
How To Remove Range For Servicing
Follow these procedures to remove appliance for
servicing:
1. Shut off gas supply to appliance.
2. Disconnect electrical supply to appliance, if equipped.
3. Disconnect gas supply tubing to appliance.
4. Slide range forward to disengage range from the
anti-tip bracket.
5. Reverse procedure to reinstall. If gas line has been
disconnected, check for gas leaks after reconnection.
NOTE: A qualified servicer should disconnect and
reconnect the gas supply.
The servicer MUST
follow installation instructions
provided with the gas appliance connector and the
warning label attached to the connector.
6. To prevent range from accidentally tipping, range must
be secured to the floor by sliding rear leveling leg into
the anti-tip bracket.
Service - Parts Information
When your range requires service or replacement parts,
contact your dealer or authorized service agency. Please
give the complete MODEL and SERIAL numbers of the
range which is located on the range model number plate.
8101P635-60
(05-04-00)
FIGURE 1
NAT
LPG