Final rinse temperature (programme
specific parameter):
^
Turn the programme selector to STOP
f.
^
Press 0 as often as necessary or
hold it pressed in until E25
(programming level 25) appears in
the display. Then:
^
Turn the programme selector to the
programme which needs to be
changed. The current value appears
in the display after °C.
^
Press ß or hold pressed in until the
required value appears in the display.
Final rinse temperature holding time
(programme specific parameter):
^
Turn the programme selector to STOP
f.
^
Press 0 as often as necessary or
hold it pressed in until E26
(programming level 26) appears in
the display. Then:
^
Turn the programme selector back to
the programme which needs to be
changed. The current value appears
in the display after min.
^
Press ß or hold pressed in until the
required value appears in the display.
Having changed a value or all values:
^ Press 6. SP appears.
^ Press 6 again. The change has
been recorded.
Programming special functions