3. Audible tone (Buzzer)
This special function allows you to
programme a buzzer (lasting up to a
maximum of 30 seconds) for the
following functions:
–
Programme end = Constant buzzer
–
Fault warning = Buzzer at one
second intervals
–
Removing a test item from the final
rinse water (this function has to be
programmed by a Miele service
engineer)
= 3 x short beeps followed by 2
second pause, then 3 short beeps
etc.
^ Turn the programme selector to STOP
f.
^ Switch off the machine.
^ Press and hold ß and 6 at the
same time, and whilst doing so,
switch the machine on with the I-0
button.
The current programme status "P..."
will appear in the display and the p /
6 indicator light will come on.
^
Press 0 four times. E04
(programming level 4) appears in the
display.
^
Turn the programme selector to q. A
number from 20 to 27 will appear in
the display.
20 = Buzzer switched off
21 = Buzzer at end of programme
(standard setting)
22 = Fault indication
23 = Fault indication and buzzer at
end of programme
24 = Reminder to remove a test item
25 = Buzzer at end of programme
and for removing a test item
26 = Fault indication and buzzer for
removing a test item
27 = Buzzer for all functions
(Programme end, Fault indication,
Removing a test item).
^
Press ß or hold pressed in until the
required value appears in the display.
^
Press 6. SP appears.
^
Press 6 again. The change has
been recorded.
Value set:
Note:
The buzzer can be switched off early
by
– turning the programme selector to
the STOP position f,
– pressing the ß button, or
– interrupting the power supply (e.g.
by opening and closing the door).
Programming special functions
37