2.3.3 Automatic Disposal:
The automated disposal process will open the drain and move oil from the vat to the filter pan,
and then close the drain once empty. The operator may now dispose of oil from the filter pan.
With no cook timers running the display will show .
To perform an automatic dispose, press the key.
If fryer is a split vat, and will be displayed. To perform a
filtering operation on the Left vat, press product key [1] (YES), or to perform a filtering
operation on the Right vat, press product key [6] (YES).
The display will show press product key [0] (NO) to
skip.
The display will show press product key [0] (NO) to
skip.
The display will show press product key [6] (YES)
to confirm.
Follow the “Initiate Check List” procedures outlined above.
Wait until automated filter process completes.
Display will return to .
2.3.4 Blocked Drain
During all automatic sequences listed above, the message ALERT DRAIN CLOSING
REMOVE TOOLS will appear with an audible alert for 10 seconds prior to the scheduled
closure of the drain. Remove tools, such as a clean-out rod, from the drain. Failure to do so
could cause damage to the equipment.
If a clean-out rod is accidently caught in a closed drain, DO NOT FORCEFULLY PULL OR
OTHERWISE TRY TO REMOVE THE TOOL. The drain will automatically reopen remove
caught tool at that time. After 10 seconds, the drain will close again and the automatic
sequence will proceed normally. If the drain is unable to close for a second time, it will
automatically reopen again and stop the return pump.
The display will scroll the message CLEAR BLOCKED DRAIN RETRY?. If there is a tool
still in the drain, remove it and press the YES key to continue. If there is no tool in the drain,
use a clean-out rod to attempt to clear any drain obstruction, remove the clean-out rod, and
press the YES key to continue. Once the drain is detected fully closed, the automatic
sequence will complete normally.
If after 3 retry attempts, or if the NO key is pressed when prompted to retry, the drain will
remain open and the fryer becomes inoperable. The display will show message OFFLINE
CALL SERVICE ERR 2002. Call for service to resolve the blocked drain issue. Other fryers
will be able to operate and filter normally.
2.4 Advanced Fryer Operations (For Automated Filtering Option):
The advanced fryer operation menu can be used to manually control the drain valve and return
pump for processes such as oil rotation, custom cleaning procedures, and recovery from an
interrupted automatic process.