Pitco Frialator 60149518 Ventilation Hood User Manual


 
Solstice I12+ Cooking Computer for ROV Fryers
Pitco P/N 60149517 & 60149518
L22-378 Rev 3 Page 8 of 44
2 Oil Handling and Fryer Operations:
2.1 Fresh Oil Top-Off:
The fresh oil top-off system allows the operator to add oil to the vat to compensate for loss due to
normal product draw-out. The top-off system is not intended for the refilling of an empty vat.
To add fresh oil to the vat on-demand, press and hold the key.
Release the Top-Off key when oil has reached an optimal level.
Use the Left or Right key to top-off the Left or Right vat, respectively, for split vat
fryers.
Manual top-offs are not permitted while there is an active cook.
This computer also supports the Auto Top-Off system (Option), where low oil levels will
automatically be detected and oil added. This system has no operator interface.
To disable the Auto Top-Off system, see section 10.8.
2.2 Manual Filtering:
This section applies to fryer configurations without the Automated Filtering option.
2.2.1 Filter Control (Option):
The filter return pump can be activated and deactivated through front panel for manual filter fryer
applications. Activating the filter return will move oil from the filter pan to the user selected frypot.
With no cook timers running the display will show , ,
, or .
To start the return pump for the vat, press the key.
If fryer is a split vat, and will be displayed. To return oil
to the Left vat, press product key [1] (YES), or to return oil to the Right vat, press product
key [6] (YES).
The display will show .
To stop the return pump, press the key again.
The display will show .