7.6 Recovery Test Value:
This controller maintains a record of heat up times for the appliance. A poorly running appliance will
have increased recovery times stored in this display. There is no selection done here, just the
display of recovery time values.
With display showing , press the product key [0].
Display will show .
Press product key 6; display will show [RECOVERY] [TEST].
Press the product key [0]. Display will show [FnnnLyyy], where nnn is the factory
recovery value, and yyy is the last warm- up recovery value.
After recording these values, press the key. Display will again return to .
7.7 Control or Timer: (Left side of Dual or Single Vat):
With display showing , press the product key [0].
Display will show .
Press product key 7; display will show [CONTROL].
Use the product key [0] to scroll through choices (Control, Timer).
Press key to save choice. Display shows .
Note: If timer is selected, heat control outputs are disabled, leaving only the timer functions active.
Do not make this selection on Solstice fryer models.
7.8 Control or Timer: (Right side of Dual Vat):
Note: This key has no function on single vat control # 60149518.
With display showing , press the product key [0].
Display will show .
Press product key 8; display will show [CONTROL].
Use the product key [0] to scroll through choices (Control, Timer).
Press [P] key to save choice. Display shows .
Note: If timer is selected, heat control outputs are disabled, leaving only the timer functions active.
Do not make this selection on Solstice fryer models.