Pitco Frialator 60149518 Ventilation Hood User Manual


 
Solstice I12+ Cooking Computer for ROV Fryers
Pitco P/N 60149517 & 60149518
L22-378 Rev 3 Page 36 of 44
10.11.2 Maximum JIB Time
This adjustment selects the amount of oil in terms of “pump time” for a full JIB. Factory default
1:30.
With display showing , press product key [2].
Display shows , where m:ss is the time the reset value
for a new JIB.
To change this value, use the product keys for numeric entry of a new value. Acceptable
entry range is 0:00 to 4:00.
Press the key to save entry.
Display returns to .
10.11.3 Low JIB Time
This adjustment selects the amount of oil remaining in terms of “pump time” for a low JIB.
Factory default 0:20.
With display showing , press product key [3].
Display shows , where m:ss is the time remaining when
“LOW JIB” is displayed.
To change this value, use the product keys for numeric entry of a new value. Acceptable
entry range is 0:00 to 4:00.
Press the key to save entry.
Display returns to .
10.11.4 JIB Monitor (Check/Fault) Enable
This selection allows the enabling and disabling of the JIB monitor for error conditions
feature.
With display showing , press product key [4].
Display shows , where xxx is either ON or OFF.
Use product key [0] change value. Press the to save choice.
Display returns to .
10.11.5 Filter Return Key Enable
This selection allows the enabling and disabling of the Filter Return key for manual filter
configurations.
With display showing , press product key [5].
Display shows , where xxx is either EN or DIS.
Use product key [0] change value. Press the to save choice.