8.8.3 Heat Demand Profile:
With display showing , press product key 3. Display will show
[xxxxxxx] [HEAT DEM], where xxxxxxx may be one of 5 heat control profiles listed below.
1. [GENERIC 1] for gas fired fryer appliance.
2. [GENERIC 2] for electric fryer appliances, and model SGH50.
3. [T-STAT] control operates as a mechanical thermostat for general applications on gas
or electric fryers. This setting offers the quickest possible recovery times at the
expense of temperature overshoot suppression.
4. [ROV1] for use with SSHLV type models only.
5. [ROV2] for use with SELV models only. This is the factory default.
Use product key [0] change value, then press the to save choice Display returns to
.
8.8.4 Shake Alarm Duration:
With display showing , press product key 4. Display will show
[SH-DUR:nn] [DURATION], where “nn” is the time in seconds the shake alarm will sound. Use
product keys for numeric entry of desired value, then press the to save choice. Display
returns to .
8.8.5 Hold Alarm Duration:
With the display showing , press product key 5. Display will
show [HD-DUR:nn] [DURATION], where “nn” is the time in seconds the hold alarm will sound.
Use product keys for numeric entry of desired value, then press the to save choice.
Display returns to .
8.8.6 Cancel Duration:
With the display showing , press product key 6. Display will
show [CANCEL:nn] [DELAY] , where “nn” is the time in seconds the operators must press a
product key to cancel a cook. Use product keys for numeric entry of desired value, then press
the to save choice. Display returns to . Default value is
2 seconds.
8.8.7 Configuration Value:
With display showing , press product key 7. Display will show
[CFG hhhh], where “hhhh” is a hexadecimal checksum of the configuration memory contained
in the controller. Modifications to any part of the setup of this control will change the check
sum value. Press the display will return to .