Pitco Frialator 60149518 Ventilation Hood User Manual


 
Solstice I12+ Cooking Computer for ROV Fryers
Pitco P/N 60149517 & 60149518
L22-378 Rev 3 Page 24 of 44
8.4 Recovery Times:
This controller maintains a record of heat up times for the appliance. A poorly running
appliance will have increased recovery times stored in this display. There is no
selection done here, just the display of recovery time values.
With display showing , press the product key [0].
Display will show .
Press product key 4; display will show [RECOVERY] [TEST].
Press the product key [0]. Display will show [FCTY nnn][RECOVERY], where nnn
is the factory recovery value.
Press the product key [0]. Display will show [OLD nnn][RECOVERY], where nnn
is the factory recovery value.
After recording these values, press the key. Display will again return to
.