10.3 Polish Time:
This adjustment controls the oil cycle time for filter operation POLISH. This value should be
selected to allow oil to make multiple passes through the filter pan. Factory default 30:00.
With display showing , press product key [3].
Display shows , where m:ss is the time
the vat will polish.
To change this value, use the product keys for numeric entry of a new
value. Acceptable entry range is 00:00 to 99:59.
Press the key to save entry. Display returns to
.
10.4 Fill Time:
This adjustment controls the vat fill time for auto-filter operations FILTER and POLISH. This
value should be selected to allow adequate time for the filter pan to be completely emptied
and return lines cleared of oil. Factory default: Full 1:15, Split 0:45.
With display showing , press product key [4].
Display shows , where m:ss is the time
the vat will fill.
To change this value, use the product keys for numeric entry of a new
value. Acceptable entry range is 0:30 to 4:00.
Press the key to save entry. Display returns to
.
10.5 Filter Temperature:
This adjustment selects the minimum oil temperature allowed for auto-filter operations to be
initiated. Manual filter operations are unaffected by this value. Factory default 275 °F.
With display showing , press product key [5].
Display shows , where nnn is the
minimum oil temperature autofilter operations can be performed, and
where X is F (Fahrenheit) or C (Celsius).
To change this value, use the product keys for numeric entry of a new
value.