Pitco Frialator 60149518 Ventilation Hood User Manual


 
Solstice I12+ Cooking Computer for ROV Fryers
Pitco P/N 60149517 & 60149518
L22-378 Rev 3 Page 20 of 44
7 To Change Options Level 2 ( for the Store Manager):
The display must show from section 2 to change these options. When the
product key [0] is pressed, the display will show . Indicator
lights above product keys will illuminate to represent options that may be changed. Each
option listed below uses the product key [0] to toggle or scroll through available choices in the
display. When the correct value is displayed, press the key to save choice. The
display will again return to for another option selection.
7.1 Fahrenheit or Celsius Display:
The Controller will display temperatures in the Fahrenheit or Celsius scales. The default scale is °F.
With display showing , press the product key [10/0].
Display shows .
Press product key 1, display shows [DEGREE n] [F OR C], where “n” is the current
setting.
Use the product key [0] to scroll through choices (F or C). Press key to save
choice.
Display shows .
7.2 Password Change or Required:
With factory settings, an operator password is not required to enter programming Levels 1 and 2.
The password may be activated or changed in these steps.
With display showing , press the product key [0].
Display will show .
Press product key 2, display shows [SET PAS] [NEW PASS]. Use the product key [0] to
scroll through choices [NO PASS] or [PASS REQ]. Press key to save choice.
If [NO PASS] is selected Display returns to .
If [PASS REQ]. is selected, display will show [PASSnnnn] [NEW PASS] to prompt for new
password. Displayed value “nnnn” is the current password. Use the product keys for numeric
entry to change password. Press [P] key to save choice. Display then shows .
Note: The factory default password (6684) will always work even if a different password is selected
here.