SITE PREPARATION
Make sure that the finished rough opening
where the Wine Storage unit is to be installed
i
s properly prepared. Refer to the Installation
Specifications illustration for rough opening
dimensions, door swing clearance and electri-
c
al placement for Models 427 and 427R.
IMPORTANT NOTE:
To operate properly, the
door must open a minimum of 90 degrees.
Use a minimum 2" (51) filler in corner installa-
tions to assure a 90-degree door opening.
Allow enough clearance in front of the unit for
full door swing.
IMPORTANT NOTE:
Make sure the floor under
the unit is level with the surrounding finished
floor.
MODELS 427 AND 427R INSTALLATION
27"
(
686)
ROUGH OPENING WIDTH
25"
(635)
R
OUGH
O
PENING
DEPTH
23
7
/8"
(606)
90˚
105˚
MAXIMUM
DOOR SWING
35" (889)
DOOR CLEARANCE
28" (711)
DOOR CLEARANCE
25
1
/2"
(648)
25
1
/2"
(648)
15
1
/2"
(394)
LOCATE ELECTRICAL
WITHIN SHADED AREA
E
4
1
/2"
(
114
)
2
1
/2"
(64)
ANTI-TIP BRACKET
FRONT VIEW
T
OP VIEW
80" (
2032)
R
OUGH OPENING
HEIGHT
T
O FINISHED
FLOORING
79
1
/2" (2019)
MIN HEIGHT
R
EQUIRED
Do not load wine into the W
ine Storage
unit until the installation is complete.
MODELS 427 AND 427R
INSTALLATION SPECIFICATIONS
NOTE: Door swing clearances are based on stainless
steel door and handle dimensions.
MODELS
427 | 427R