Sub-Zero 424/O Beverage Dispenser User Manual


 
21
Dimensions in parentheses are in
millimeters unless otherwise specified.
With the Wine Storage unit secured in position
a
nd the door closed, the panel is held in the
desired position on the door and rapped by
hand from the front, putting center marks on
the rear surface of the panel. If the door panel
is made of such a material that pre-drilling is
needed, all of the mounting holes should be
marked. If not, only enough holes to hold the
panel in place temporarily, are necessary.
The door panel is then lowered from the door
frame, tenon centers removed, the door
opened and the screws driven into the panel
through the black tape on the door frame,
using the center marks to locate the screws.
The screw holes inside the door are hidden
under a cover flap on the door gasket. It is
necessary to lift the flap to insert the screws.
Use as many screws as necessary to hold the
door panel in place properly.
IMPORTANT NOTE:
After the first three or
four mounting screws are in place, but not
completely tightened, close the door and check
your panel fit. This is the time to make small
adjustments. Once you are satisfied with the
appearance, open the door and apply the
remainder of the screws. Check all screws for
tightness.
The metal frame on the glass door has
numerous mounting holes on each side of the
door. This is to accommodate the Sub-Zero
accessory handles and provide for easy attach-
ment of the handle through the door frame.
If you choose not to use the pre-drilled handle
mounting holes, it will be necessar
y to fasten
the handle from the rear of the door panel
only, or drill one or more additional holes
thr
ough the metal frame of the glass door
.
Illustration 12 on page 20 shows how this hole
passes through the door frame. The hole
c
enter is on the small locator groove in the
front of the frame. A
1
/4" (6) diameter hole is
made in the front wall of the extrusion and a
13
/32"
(11) diameter hole through the rest of the
frame.
IMPORTANT NOTE:
Install screws in all the
mounting holes in the door frame. The nature
of the door panel with a narrow outer rim and
no connecting center member requires the
support provided by the glass door.
After the door panel installation is complete,
apply the cover patches or plugs provided over
the holes on the inside surface of the door.
MODELS 427 AND 427R INSTALLATION
The cover patches or plugs are part of the
insulation system on the door of the Wine
Storage unit. Be sure to cover all the
holes in the door that wer
e used.
The wine storage unit door is made with
a sealed double wall tempered glass core.
The drill must not contact this core when
drilling. Be sure the hole is centered on
the small groove in the front of the door
frame and the drill passes squarely
through the frame. If you are inexperi-
enced with drilling, fasten the handle from
the r
ear of the door panel only.
MODELS
427 | 427R