Planning Information
A minimum height clearance of 6
1
/4" (159) is required from
the top of the countertop to any combustible surface
directly below the cooktop.
Contemporary induction and electric cooktops can be
mounted ush with the top of the countertop, or as a frame-
less installation sitting on top of the countertop surface. In
either installation the cooktop cut-out dimensions are the
same. If the cooktop is to be mounted ush with the coun-
tertop, a recessed area surrounding the cooktop cut-out
must be provided. Wolf downdraft systems cannot be used
with contemporary induction and electric cooktops.
IMPORTANT NOTE: Flush mount installations are intended
for granite, solid surface or stone countertop surfaces only.
ELECTRICAL
ELECTRICAL REQUIREMENTS
Electrical Supply grounded 3-wire, 240/208 VAC, 60 Hz
CT30E-208/S grounded 3-wire, 208 VAC, 60 Hz
15" Cooktop 20 amp dedicated circuit
30" Cooktop 40 amp dedicated circuit
36" Cooktop 50 amp dedicated circuit
Conduit exible 4'
(1.2 m)