Planning Information
The platform must be able to support 200 lbs (91 kg) for a
30" rangetop, 250 lbs
(113 kg) for a 36" rangetop and 300 lbs
(136 kg)
for a 48" rangetop. The platform must include a
cut-out for gas supply and electrical connections.
When installing against a combustible surface, a minimum
5"
(127) riser is required for model SRT366, and a minimum
10"
(254) riser is required for 36" and 48" sealed burner
rangetops with a charbroiler or griddle. Follow all minimum
clearances to combustible surfaces shown in the illustration
on the following page.
It is recommended that you use a Wolf pro ventilation hood
or hood liner with the sealed burner rangetop. If the ran-
getop is to be installed without ventilation, a 36"
(914) min-
imum clearance, 44"
(1118) for charbroiler, from countertop
to combustible materials above the rangetop is required.
Refer to page 92 for pro ventilation.
A downdraft can be used with models SRT304 and SRT366.
An accessory trim kit is necessary for this installation. Con-
tact an authorized Wolf dealer for details.
ELECTRICAL
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 110/120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 6'
(1.8 m)
GAS SUPPLY
A gas supply line of
3
/4" (19) rigid pipe must be provided to
the rangetop. If local codes permit, a certied, 3'
(.9 m) long,
1
/2" (13) or
3
/4" (19) ID exible metal appliance connector is
recommended to connect the units
1
/2" NPT female inlet to
the gas supply line.
Wolf natural gas rangetops will function up to 10,250'
(3124 m)
in altitude without adjustment and LP gas ran-
getops up to 8,600'
(2621 m). If the installation exceeds
these elevations, contact an authorized Wolf dealer for a
high altitude conversion kit.
GAS SUPPLY REQUIREMENTS
NATURAL GAS
Gas Supply Pressure 5" (12.5 mb) WC
Min Line Pressure 7"
(17.5 mb) WC
Max Pressure to Regulator 14"
(34.9 mb) WC, .5 psi (3.5 kPa)
LP GAS
Gas Supply Pressure 10" (25 mb) WC
Min Line Pressure 11"
(27.4 mb) WC
Max Pressure to Regulator 14" (34.9 mb) WC, .5 psi (3.5 kPa)