Planning Information
The oven can be installed in a standard or ush inset
application. If a cooktop is being installed above an oven,
a minimum of
1
/4" (6) is required between units. Location of
the electrical supply within the oven opening may require
additional cabinet depth. Refer to the chart below.
Finish the edges of the opening. They may be visible when
the door is open.
For ush inset installations, a minimum
1
/4" (6) reveal is
required on all sides. To ensure consistent
1
/4" (6) reveals,
each corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT
Single Oven 250 lb (115 kg)
Double Oven 400 lb (181 kg)
TRIM OVERLAP TOP BOTTOM SIDES
30" E Series Oven
1
/2" (13)
1
/8" (3)
11
/16" (17)
30" L Series Oven
1
/8" (3)
1
/8" (3)
11
/16" (17)
36" L Series Oven
3
/16" (5)
1
/8" (3)
9
/16" (14)
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply ush with the back wall and
within the shaded area shown in the illustration for your spe-
cic installation on the following pages. For ease of instal-
lation, the electrical supply for the oven can be placed in an
adjacent cabinet within reach of the conduit.
Performance may be compromised if the electrical supply is
less than 240 volts.
The oven is supplied with a conduit consisting of two
insulated hot lead conductors and a bare ground conductor.
The wiring diagram covering the control circuit is provided
with the oven.
ELECTRICAL REQUIREMENTS
SINGLE OVEN
Electrical Supply grounded, 240/208 V AC, 60 Hz
Service 30 amp dedicated circuit
Conduit 4'
(1.2 m), 3' (.9 m) for SO36U
Total Amps 21
Max Connected Load 5.1 kW
Min Supply Wire L1, L2, ground—10 AWG
DOUBLE OVEN
Electrical Supply grounded, 240/208 V AC, 60 Hz
Service 50 amp dedicated circuit
Conduit 5'
(1.5 m)
Total Amps 37
Max Connected Load 8.9 kW
Min Supply Wire L1, L2, ground—10 AWG