Thermador PH30HS Ventilation Hood User Manual


 
English 11
Cabinet Installation
The hood can be installed under a cabinet by supporting
the hood from the top.
Note:
The cabinet must be structurally joined to the wall studs to
support the weight of this hood.
Figure 15 shows the (4) screw holes labeled “K” used for
mounting the hood to the bottom of the cabinet. Make sure
both knockouts have been removed.
1. In the base of the cabinet, drill 1/8” (3 mm) tap holes as
indicated in Dimension A in Figure 15 and in Table 2.
2. Screw in (4) 1" (25 mm) screws (provided with hood)
leaving 1/4” (6 mm) exposed to hang hood on.
3. If the hood is installed for vertical discharge, refer to
Figure 16 to create clearance holes for passage of the
transition and conduit. Refer to Dimension B in
Figure 16 and Table 2.
4. For horizontal discharge, use Figure 9 on page 9 for
the geometry of the cutout required for clearance of the
transition.
5. Hang hood from screws and tighten securely.
6. From inside of hood, insert screws supplied. Drill
through holes, use 5/8” (16 mm) screws supplied, (1)
on each side and (4) along the front, into bottom of the
cabinet. See screw holes labeled "L" in Figure 15.
Figure 15: Tap Hole and Screw Hole Locations
A
K
K
L
L
L
23”
(584 mm)
1
9
/16
(40 mm)
7
1
/16
(179 m
m)
Note:
This figure depicts tap hole and screw hole locations
only. See Figure 1 on page 3 for overall hood
dimensions.
Figure 16: Transition and Conduit Locations
HOOD
SIZE
Tap Holes
A, Figure 15
Conduit Holes
B, Figure 16
30” (762 mm) 29” (736 mm) 13” (330 mm)
36” (914 mm) 35” (889 mm) 16” (406 mm)
42” (1067 mm) 41” (1041 mm) 19” (483 mm)
48” (1219 mm) 47” (1194 mm) 22” (559 mm)
54” (1372 mm) 53” (1346 mm) 25” (635 mm)
Table 2: Centerline Hole Dimensions for Tap and Conduit
Holes
23"
(584 mm)
Wall
B
Cooktop
Centerline
Plan View of Cabinet Cutout
5/8" (16 mm) DIA
clearance holes for
½" (12.7 mm) conduit
to j-box.
2
3
/8
(60 mm)
1
7
/8
(48 mm
)
1
1
/8
(
29 mm)
3
3
/16
(81 mm)
7
7
/8
(200 mm)
2
3
/8
(60mm)