Thermador PH30HS Ventilation Hood User Manual


 
English 12
Blower Motor Installation
All hoods require the choice of a Remote, Inline, or Integral
Blower. Use only THERMADOR
®
blowers with
THERMADOR ventilation hoods. All blower models are
sold separately. See Table 3 Blower & Circuit Breaker
Ratings for recommended blowers. Contact Customer
Service for additional options.
All Hood models are rated for 120 VAC, using a 15 amp or
20 amp circuit breaker.
Blower selection will vary based on the volume of air that
needs to be moved and the length and location of the duct
run. For long duct runs with multiple turns and bends,
consider using a more powerful blower. For the most
efficient air-Àow exhaust, use a straight run or as few
elbows as possible (refer to “Ductwork Preparation” on
page 4).
For indoor grill installations, THERMADOR recommends a
minimum of 36" (914 mm) clearance to the bottom of the
ventilation unit and Remote or Inline blowers only.
Integral Blower Installation Only
1. The blower is attached to the hood using weld studs
provided on the mounting plate. Figure 17 displays the
weld stud locations.
2. Guide the motor mounting plate over the studs.
3. Attach (4) nuts (included with hood) to the weld studs.
Tighten nuts to secure the blower to the hood.
4. Continue to “Wiring the Hood with an Integral Blower”
on page 13.
Blower SKU CFM Voltage (AC)
Blower Current
(AMPS)
Circuit Breaker
(AMPS)
Remote Blower 600 CFM VTR630D 600 120 4.2 15
Remote Blower 1000 CFM VTR1030D 1000 120 5.7 15
Remote Blower 1300 CFM VTR1330E 1300 120 8.5 20* / 15**
Inline Blower 600 CFM VTI610D 600 120 4.2 15
Inline Blower 1000 CFM VTI1010D 1000 120 5.7 15
Integral Blower 600 CFM VTN630C 600 120 2.7 15
Integral Blower 1000 CFM VTN1030C 1000 120 5.4 15
* 20 Amp circuit breaker required when using the VTR1330E Remote Blower with a 27” Pro Wall Hood.
** 15 Amp circuit breaker required when using the VTR1330E Remote Blower with a 24” Pro Wall Hood.
Table 3: Blower & Circuit Breaker Ratings
WARNING:
Cutting the plug of the blower will void the warranty or
eligibility for return or exchange.
CAUTION:
To reduce the risk of fire and electric shock, install this
range hood only with the blowers listed in Table 3.
Figure 17: Weld Stud Locations