Thermador PH30HS Ventilation Hood User Manual


 
English 7
Hood Transition
The supplied transition mounts to the top or rear of the
hood depending on the discharge direction.
Assembly of the Transition:
A minimum height clearance of 6” (152 mm) is needed
above the hood for transition mounting. See Figure 1 on
page 3 for overall hood dimensions.
1. Depending on direction of discharge, align mounting
holes at base of transition with the mounting holes of
the ½” (13 mm) flange located at the top or rear of the
hood.
2. Fasten transition to hood using (2) 1” (25.4 mm) sheet
metal screws included with hood.
3. Seal connection between transition and hood with
aluminum tape.
4. Remove tape holding damper closed.
Figure 3: Transition
Figure 4: Transition Cutout Dimensions
10”
(254 mm)
Duct
21¾” (553 mm)
4
5
16
(110 mm)
/
1” (25.4 mm)
screw x 2
21¾”
(553 mm)
4¼”
(108 mm)
(43 mm)
11
/
16
1
Figure 5: Transition Connection
3
2
1