Thermador PH30HS Ventilation Hood User Manual


 
English 1
Safety
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
APPROVED FOR ALL RESIDENTIAL APPLIANCES
FOR RESIDENTIAL USE ONLY
Before You Begin
IMPORTANT: Save these Instructions for the Local Gas
Inspector’s use.
INSTALLER: Please leave these Instructions with this unit
for the owner.
OWNER: Please retain these instructions for future
reference.
Safety Codes and Standards
This appliance complies with the following Standards:
UL 507, Standard for the Safety of Electrical Fans
CAN/CSA-C22.2 No. 113, Fans and Ventilators
It is the responsibility of the owner and installer to
determine if additional requirements and/or standards
apply to specific installations. Always refer to local codes to
ensure all requirements are met.
If required by the National Electrical Code (or Canadian
Electrical Code), this appliance must be installed on a
separate branch circuit.
INSTALLER — show the owner the location of the circuit
breaker or fuse. Mark it for easy reference.
Never modify or alter the construction of the appliance. For
example, do not remove panels or wire covers.
WARNING:
If the information in this manual is not followed exactly,
fire or shock may result causing property damage or
personal injury.
Do not repair or replace any part of the appliance unless
specifically recommended in the manuals. Improper
installation, service or maintenance can cause injury or
property damage or void product warranty. Refer to this
manual for guidance. All other servicing should be done
by a qualified technician.
CAUTION:
The unit is heavy and should be handled
accordingly. Proper safety equipment such
as gloves and adequate manpower of at
least two people must be used in moving the
hood to avoid injury and to avoid damage to
the unit or the floor. Rings, watches, and any
other loose items that may damage the unit
or otherwise might become entangled with
the unit should be removed.
Hidden surfaces may have sharp edges.
Use caution when reaching behind or under
appliance.
WARNING:
Turn off power circuit at service panel and lock out panel
before wiring this appliance. Requirement: 120 VAC, 60
Hz 20 A. Allow the appliance to cool after the power has
been turned off before servicing the appliance.
WARNING:
To reduce the risk of fire use only metal ductwork.
CAUTION:
Vent unit to the outside of building only. This unit is only
designed to be vented outside. It should not be used for
recirculation mode.