Typical Product Description Block
MODL CVHE DSEQ 2R NTON 320 VOLT 575 REF 123
HRTZ 60 TYPE SNGL CPKW 142 CPIM 222 TEST AIR
EVTM IECU EVTH 28 EVSZ 032S EVBS 280
EVWC STD EVWP 2 EVWT NMAR EVPR 150
EVCO VICT EVWA LELE CDTM IECU CDTH 28
CDSZ 032S CDBS 250 CDWC STD CDWP 2
CDWT NMAR CDPR 150 CDCO VICT CDWA LELE
CDTY STD TSTY STD ECTY WEOR ORSZ 230
PURG PURE WCNM SNMP SPKG DOM OPTI CPDW
HHOP NO GENR NO GNSL NO SOPT SPSH
ACCY ISLS HGBP WO LUBE SNGL AGLT CUL
CNIF UCP SRTY USTR SRRL 207 PNCO TERM
General
Information
Unit Nameplate
The unit nameplate is located on the
left side of the unit control panel.
The following information is
provided on the unit nameplate.
1. Serial Number
The unit serial number provides the
specific chiller identity. Always
provide this serial number when
calling for service or during parts
identification..
2. Service Model Number
The service model represents the unit
as built for service purposes . It
identifies the selections of variable
unit features required when ordering
replacements parts or requesting
service.
Note: Unit-mounted starters are
identified by a separate number
found on the starter.
3. Product Coding Block
The CVHE, CVHF and CVHG models
are defined and built using the
product definition and selection
(PDS) system. This system describes
the product offerings in terms of a
product coding block which is made
up of feature categories and feature
codes. An example of a typical
product code block is given on this
page. The coding block precisely
identifies all characteristics of a unit.
4. Identifies unit electrical
requirements
5. Correct operating charges and type
of refrigerant
6. Unit Test Pressures and Maximum
Operating Pressures
7. Identifies unit Installation and
Operation and Maintenance manuals
8. Drawing numbers for Unit Wiring
Diagrams
Literature change
Applicable to CVHE, CVHF, CVHG
About this manual
Operation and maintenance
information for models CVHE, CVHF
and CVHG are covered in this
manual. This includes both 50 and 60
Hz. CVHE, CVHF and CVHG
centrifugal chillers equipped with the
Tracer CH530 Chiller Controller
system. Please note that information
pertains to all three chiller types
unless differences exist in which
case the sections are broken down
by Chiller type as applicable and
discussed separately.
By carefully reviewing this
information and following the
instructions given, the owner or
operator can successfully operate
and maintain a CVHE, CVHF or CVHG
unit.
If mechanical problems do occur,
however, contact a qualified service
organization to ensure proper
diagnosis and repair of the unit.
Note: The CH530 controller was first
applied to CVHE with Design
Sequence “3K”, and to CVHF with
Design Sequence “1W”.