VII. OPERATING THE BLAST CHILL CONTROL - STARTING A CHILL CYCLE
-12-
VII. a - STARTING A CHILL CYCLE - BY TEMP (contd):
STEP SIX: Select the done probe(s) by pressing the button(s) to the left
or right of where that number probe(s) is displayed. Remove
all product associated with the done probe(s) from the
chiller. If all probes have completed their respective batches,
the display changes to the HOLDING screen menu.
To remove a product before it is completed press the button to
the right of where ADD/REMOVE is shown on the display.Select
any other probes number to stop cycle and remove it. Answer,
by pressing the button to the left/right of where NO/YES is
shown on the display.
STEP SEVEN: The display will ask if you want to print a chill cycle data report
and/or label for that particular probe.
1) RECORD = Print probe report on standard printer only
2) LABEL = Print probe report on label printer only
3) BOTH = Print probe report on both standard and label
printers.
To continue chilling without printing either, press the button
to the left of where NONE is shown on the display.
To print a chill report for this probe, press the button to the right
of where RECORD is shown on the display.
To print a label for this probe, press the button to the right
of where LABEL is shown on the display.
To print a both chill report and label for this probe, press the
button to the right of where BOTH is shown on the display.
Multiple records and/or labels may be printed by pressing the
appropriate button after previous printing is completed. When
finished printing press NONE and the display will return to the
MAIN MENU or PROBE MENU if there are still active probes.
Repeat as necessary when each probe reaches completion.
When all probes are DONE, return to the MAIN MENU.
HOLDING AIR 37°F
1 DONE DONE 3
2 DONE
1:16:01 ADD/REMOVE
CHILLING AIR 14°F
1 41°F DONE 3
2 44°F
1:16:08 CONTINUE
SELECT PROBE:
1 39°F REMOVE 3
2 44°F
1:16:28 CONTINUE
STOP CYCLE ON #2
REMOVE PRODUCT?
NO YES
PRINT PROBE #
RECORD
LABEL
NONE BOTH